    Oxford Instruments 3d-reconstruction image analysis processing software
    <t>Imaris</t> snapshot images of confocal z-stack projections that visualise the entire depth of the retinal fibre layer where both astrocytes and blood vessels are situated. The overlapping immunohistochemistry represents connexin heterogeneity in gap junction plaques expressed by astrocytes and captured using high resolution three-dimensional projection, simulated fluorescence processing and orthogonal mode camera dialogue. The GFAP and GS isolectin B4 stain were omitted from these images to better illustrate the fluorescence of the connexins. A&C were taken in the central retinal region and B&D from a peripheral retinal region. A&C and B&D are a different angle of the same <t>3D</t> analysis to show different connexin combinations as indicated by the arrows. Immunostaining of astrocyte connexins represents Cx26 (blue), Cx30 (red), Cx43 (green) and Cx45 (brown). Different colocalisation patterns of connexin proteins in diverse astrocyte connexin hemichannels were qualitatively analysed (1Cx protein, small arrows, 2Cx and 3Cx proteins, curved arrows, and 4Cx proteins, large arrowheads). All images are highly zoomed and rendered confocal z-slice projections. For qualitative purposes, displayed images were also constructed using automated scale bar, object frame (grid, tickmarks and box) and XYZ clipping plane (i.e. crops object below the plane). The set camera angle logarithmic functions were also applied to measure angle, elevation and azimuth parameters for each of the images represented. This was as follows: angle = −5.6521 (A), 4.4572 (B), −6.3247 (C), −0.0729 (D), elevation = 91.8453 (A), 88.6771 (B), 93.7761 (C), 90.0196 (D), azimuth = 119.9393 (A), −65.222 (B), 127.6513 (C), 93.3840 (D).
    3d Reconstruction Image Analysis Processing Software, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/3d+reconstruction+image+processing/3d+reconstruction+software+vy402w2cq5mh/pmc03597639-120-23-22
    Average 90 stars, based on 1 article reviews
    3d-reconstruction image analysis processing software - by Bioz Stars, 2026-11
    90/100 stars

    Images

    1) Product Images from "Connexin 30 Expression and Frequency of Connexin Heterogeneity in Astrocyte Gap Junction Plaques Increase with Age in the Rat Retina"

    Article Title: Connexin 30 Expression and Frequency of Connexin Heterogeneity in Astrocyte Gap Junction Plaques Increase with Age in the Rat Retina

    Journal: PLoS ONE

    doi: 10.1371/journal.pone.0057038

    Imaris snapshot images of confocal z-stack projections that visualise the entire depth of the retinal fibre layer where both astrocytes and blood vessels are situated. The overlapping immunohistochemistry represents connexin heterogeneity in gap junction plaques expressed by astrocytes and captured using high resolution three-dimensional projection, simulated fluorescence processing and orthogonal mode camera dialogue. The GFAP and GS isolectin B4 stain were omitted from these images to better illustrate the fluorescence of the connexins. A&C were taken in the central retinal region and B&D from a peripheral retinal region. A&C and B&D are a different angle of the same 3D analysis to show different connexin combinations as indicated by the arrows. Immunostaining of astrocyte connexins represents Cx26 (blue), Cx30 (red), Cx43 (green) and Cx45 (brown). Different colocalisation patterns of connexin proteins in diverse astrocyte connexin hemichannels were qualitatively analysed (1Cx protein, small arrows, 2Cx and 3Cx proteins, curved arrows, and 4Cx proteins, large arrowheads). All images are highly zoomed and rendered confocal z-slice projections. For qualitative purposes, displayed images were also constructed using automated scale bar, object frame (grid, tickmarks and box) and XYZ clipping plane (i.e. crops object below the plane). The set camera angle logarithmic functions were also applied to measure angle, elevation and azimuth parameters for each of the images represented. This was as follows: angle = −5.6521 (A), 4.4572 (B), −6.3247 (C), −0.0729 (D), elevation = 91.8453 (A), 88.6771 (B), 93.7761 (C), 90.0196 (D), azimuth = 119.9393 (A), −65.222 (B), 127.6513 (C), 93.3840 (D).
    Figure Legend Snippet: Imaris snapshot images of confocal z-stack projections that visualise the entire depth of the retinal fibre layer where both astrocytes and blood vessels are situated. The overlapping immunohistochemistry represents connexin heterogeneity in gap junction plaques expressed by astrocytes and captured using high resolution three-dimensional projection, simulated fluorescence processing and orthogonal mode camera dialogue. The GFAP and GS isolectin B4 stain were omitted from these images to better illustrate the fluorescence of the connexins. A&C were taken in the central retinal region and B&D from a peripheral retinal region. A&C and B&D are a different angle of the same 3D analysis to show different connexin combinations as indicated by the arrows. Immunostaining of astrocyte connexins represents Cx26 (blue), Cx30 (red), Cx43 (green) and Cx45 (brown). Different colocalisation patterns of connexin proteins in diverse astrocyte connexin hemichannels were qualitatively analysed (1Cx protein, small arrows, 2Cx and 3Cx proteins, curved arrows, and 4Cx proteins, large arrowheads). All images are highly zoomed and rendered confocal z-slice projections. For qualitative purposes, displayed images were also constructed using automated scale bar, object frame (grid, tickmarks and box) and XYZ clipping plane (i.e. crops object below the plane). The set camera angle logarithmic functions were also applied to measure angle, elevation and azimuth parameters for each of the images represented. This was as follows: angle = −5.6521 (A), 4.4572 (B), −6.3247 (C), −0.0729 (D), elevation = 91.8453 (A), 88.6771 (B), 93.7761 (C), 90.0196 (D), azimuth = 119.9393 (A), −65.222 (B), 127.6513 (C), 93.3840 (D).

    Techniques Used: Immunohistochemistry, Fluorescence, Staining, Immunostaining, Construct

    Related Articles

    Image Reconstruction:

    Article Title: CD9 regulates macrophage-mediated remodeling of adipose tissue in obesity.
    Article Snippet: .. 3D image reconstruction was performed in Imaris 549 software (v8.1.2, Oxford Instruments). ..

    Article Title: CD9 regulates macrophage-mediated remodeling of adipose tissue in obesity
    Article Snippet: .. All fluorescent staining (blue, green, red, and far-red channels) were acquired using HyD detectors in the standard mode with 100% gain, and 3D image reconstruction was performed with Imaris software (v8.1.2, Oxford Instruments). ..

    Article Title: Development of Novel Technology for the Visualization and Quantitation of Angiogenesis and the Alveolar-Capillary Network in a Mouse Model of Fibrosis.
    Article Snippet: Affiliations: 1Department of Medicine, Division of Pulmonary, Critical Care & Sleep Medicine, National Jewish Health, Denver CO, 80206; 2Cell, Stem Cell and Development Graduate Program, University of Colorado Anschutz Medical Campus, Aurora, CO; 3Department of Medicine, University of Colorado Anschutz Medical Campus, Aurora, CO; 4Onimagin Technologies SCA, Cordoba, Spain; 5Gates Center for Regenerative Medicine and Stem Cell Biology, University of Colorado, Aurora, CO, 80045.

    Software:

    Article Title: CD9 regulates macrophage-mediated remodeling of adipose tissue in obesity.
    Article Snippet: .. 3D image reconstruction was performed in Imaris 549 software (v8.1.2, Oxford Instruments). ..

    Article Title: Upregulation of Na/H Exchanger in Astrogliosis and Early Alzheimer’s Disease Pathogenesis
    Article Snippet: .. Data are represented as mean ± SEM. (****p<0.0001, n=20, 2-way ANOVA, Bonferroni’s Multiple comparisons Test, Kolmogorov-Smirnov test for Normality used). ( C ) Intensity profile analysis of overlapping GFAP and NHE1 signals in Aβ- and Aβ+ areas with Nikon NIS Elements Analysis Software. ( D ) Representative Imaris 3D reconstruction image and zoomed image of extended surface of Aβ aggregate (blue arrow), GFAP + astrocyte volume (pink arrow), and NHE1 expression spots (green arrow) in GFAP + astrocytes of APP mouse cortex. ( E ) Percentage of GFAP volume per field (****p<0.0001). .. Data are represented as mean ± SEM. (****p<0.0001, n=20, 2-way ANOVA, Bonferroni’s Multiple comparisons Test, Kolmogorov-Smirnov test for Normality used). ( C ) Intensity profile analysis of overlapping GFAP and NHE1 signals in Aβ- and Aβ+ areas with Nikon NIS Elements Analysis Software. ( D ) Representative Imaris 3D reconstruction image and zoomed image of extended surface of Aβ aggregate (blue arrow), GFAP + astrocyte volume (pink arrow), and NHE1 expression spots (green arrow) in GFAP + astrocytes of APP mouse cortex. ( E ) Percentage of GFAP volume per field (****p<0.0001).

    Sequencing:

    Article Title: Migrating mesoderm cells self-organize into a dynamic meshwork structure during chick gastrulation
    Article Snippet: .. From this 2D image sequence, we constructed a z-stack image using the 3D image reconstruction function of IMARIS by setting the z-interval at 5 μm. .. Each hole was visualized by the ‘surface ’ function in IMARIS.

    Construct:

    Article Title: Migrating mesoderm cells self-organize into a dynamic meshwork structure during chick gastrulation
    Article Snippet: .. From this 2D image sequence, we constructed a z-stack image using the 3D image reconstruction function of IMARIS by setting the z-interval at 5 μm. .. Each hole was visualized by the ‘surface ’ function in IMARIS.

    Microscopy:

    Article Title: Peptide compound with repetitive sequences
    Article Snippet: The number of live and dead cells are counted using imageJ software, and the percentage of cell viability is calculated as the average ratio of live to total cells. .. Z-stack images are acquired using an inverted laser scanning confocal microscope (ZeissTM LSM 880 Inverted Confocal Microscope, Germany), and 3D image reconstruction is performed using Imaris software. ..

    Staining:

    Article Title: CD9 regulates macrophage-mediated remodeling of adipose tissue in obesity
    Article Snippet: .. All fluorescent staining (blue, green, red, and far-red channels) were acquired using HyD detectors in the standard mode with 100% gain, and 3D image reconstruction was performed with Imaris software (v8.1.2, Oxford Instruments). ..

    Expressing:

    Article Title: Upregulation of Na/H Exchanger in Astrogliosis and Early Alzheimer’s Disease Pathogenesis
    Article Snippet: .. Data are represented as mean ± SEM. (****p<0.0001, n=20, 2-way ANOVA, Bonferroni’s Multiple comparisons Test, Kolmogorov-Smirnov test for Normality used). ( C ) Intensity profile analysis of overlapping GFAP and NHE1 signals in Aβ- and Aβ+ areas with Nikon NIS Elements Analysis Software. ( D ) Representative Imaris 3D reconstruction image and zoomed image of extended surface of Aβ aggregate (blue arrow), GFAP + astrocyte volume (pink arrow), and NHE1 expression spots (green arrow) in GFAP + astrocytes of APP mouse cortex. ( E ) Percentage of GFAP volume per field (****p<0.0001). .. Data are represented as mean ± SEM. (****p<0.0001, n=20, 2-way ANOVA, Bonferroni’s Multiple comparisons Test, Kolmogorov-Smirnov test for Normality used). ( C ) Intensity profile analysis of overlapping GFAP and NHE1 signals in Aβ- and Aβ+ areas with Nikon NIS Elements Analysis Software. ( D ) Representative Imaris 3D reconstruction image and zoomed image of extended surface of Aβ aggregate (blue arrow), GFAP + astrocyte volume (pink arrow), and NHE1 expression spots (green arrow) in GFAP + astrocytes of APP mouse cortex. ( E ) Percentage of GFAP volume per field (****p<0.0001).

    other:

    Article Title: Functional profiling of extracellular vesicles from boar reproductive fluids
    Article Snippet: Sperm-EV interaction was further confirmed by double lipophilic staining, which enabled visualization of EVs’ interaction with the sperm surface and monitoring of binding dynamics using Imaris visualization.



    Similar Products

    90
    MathWorks Inc 3d reconstruction image processing
    3d Reconstruction Image Processing, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/3d+reconstruction+image+processing/pmc10942781-213-2-6
    Average 90 stars, based on 1 article reviews
    3d reconstruction image processing - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc code for 3d reconstruction image processing (matlab)
    Code For 3d Reconstruction Image Processing (Matlab), supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/3d+reconstruction+image+processing/10__7554_slash_elife__92614-252-2-6
    Average 90 stars, based on 1 article reviews
    code for 3d reconstruction image processing (matlab) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Oxford Instruments 3d-reconstruction image analysis processing software
    <t>Imaris</t> snapshot images of confocal z-stack projections that visualise the entire depth of the retinal fibre layer where both astrocytes and blood vessels are situated. The overlapping immunohistochemistry represents connexin heterogeneity in gap junction plaques expressed by astrocytes and captured using high resolution three-dimensional projection, simulated fluorescence processing and orthogonal mode camera dialogue. The GFAP and GS isolectin B4 stain were omitted from these images to better illustrate the fluorescence of the connexins. A&C were taken in the central retinal region and B&D from a peripheral retinal region. A&C and B&D are a different angle of the same <t>3D</t> analysis to show different connexin combinations as indicated by the arrows. Immunostaining of astrocyte connexins represents Cx26 (blue), Cx30 (red), Cx43 (green) and Cx45 (brown). Different colocalisation patterns of connexin proteins in diverse astrocyte connexin hemichannels were qualitatively analysed (1Cx protein, small arrows, 2Cx and 3Cx proteins, curved arrows, and 4Cx proteins, large arrowheads). All images are highly zoomed and rendered confocal z-slice projections. For qualitative purposes, displayed images were also constructed using automated scale bar, object frame (grid, tickmarks and box) and XYZ clipping plane (i.e. crops object below the plane). The set camera angle logarithmic functions were also applied to measure angle, elevation and azimuth parameters for each of the images represented. This was as follows: angle = −5.6521 (A), 4.4572 (B), −6.3247 (C), −0.0729 (D), elevation = 91.8453 (A), 88.6771 (B), 93.7761 (C), 90.0196 (D), azimuth = 119.9393 (A), −65.222 (B), 127.6513 (C), 93.3840 (D).
    3d Reconstruction Image Analysis Processing Software, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/3d+reconstruction+image+processing/3d+reconstruction+software+vy402w2cq5mh/pmc03597639-120-23-22
    Average 90 stars, based on 1 article reviews
    3d-reconstruction image analysis processing software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc image processing and 3d reconstruction
    a SteAS-based trapping of a single fluorescent PS particle (5 μm). When the power was applied, particles are trapped and suspended in the microchannel. b When the power is turned off, the particles settle to the surface. c A suspended particle is trapped and rotated in the AST under the combined effect of radiation force and drag force. The stacked image sequences (6 images, 27 ms apart) are captured at approximately 10 mW. The green dotted circle represents the range of trapping points. The red arrows show the direction of particle rotation. The yellow dotted rectangle shows the position of the UHF device. d Pattern of individual cells based on the AST. HeLa cells stained with calcein-AM (green) are used to represent the size and profile of the trapping point. The white arrow represents the direction of lateral flow, the red arrows show the trajectories of individual cells in SteAS, the white dotted pentagon is the position of the UHF device, and the blue curved rectangles represent the profile of the AST. e A single cluster trapped in the AST. The cells are highlighted by pseudocolor (red). The detailed images show the images before and after image processing. The rotation axis and direction are represented by a blue dotted line and a blue arrow, respectively. f The result of <t>3D</t> <t>reconstruction.</t>
    Image Processing And 3d Reconstruction, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/3d+reconstruction+image+processing/pmc09352906-209-4-9
    Average 90 stars, based on 1 article reviews
    image processing and 3d reconstruction - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Autodesk Inc 3d image processing reconstruction software 123d version 4.2
    a SteAS-based trapping of a single fluorescent PS particle (5 μm). When the power was applied, particles are trapped and suspended in the microchannel. b When the power is turned off, the particles settle to the surface. c A suspended particle is trapped and rotated in the AST under the combined effect of radiation force and drag force. The stacked image sequences (6 images, 27 ms apart) are captured at approximately 10 mW. The green dotted circle represents the range of trapping points. The red arrows show the direction of particle rotation. The yellow dotted rectangle shows the position of the UHF device. d Pattern of individual cells based on the AST. HeLa cells stained with calcein-AM (green) are used to represent the size and profile of the trapping point. The white arrow represents the direction of lateral flow, the red arrows show the trajectories of individual cells in SteAS, the white dotted pentagon is the position of the UHF device, and the blue curved rectangles represent the profile of the AST. e A single cluster trapped in the AST. The cells are highlighted by pseudocolor (red). The detailed images show the images before and after image processing. The rotation axis and direction are represented by a blue dotted line and a blue arrow, respectively. f The result of <t>3D</t> <t>reconstruction.</t>
    3d Image Processing Reconstruction Software 123d Version 4.2, supplied by Autodesk Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/3d+reconstruction+image+processing/123d+design/pm33027540-23-13-19
    Average 90 stars, based on 1 article reviews
    3d image processing reconstruction software 123d version 4.2 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Thermo Fisher 3d reconstructions image processing software
    a SteAS-based trapping of a single fluorescent PS particle (5 μm). When the power was applied, particles are trapped and suspended in the microchannel. b When the power is turned off, the particles settle to the surface. c A suspended particle is trapped and rotated in the AST under the combined effect of radiation force and drag force. The stacked image sequences (6 images, 27 ms apart) are captured at approximately 10 mW. The green dotted circle represents the range of trapping points. The red arrows show the direction of particle rotation. The yellow dotted rectangle shows the position of the UHF device. d Pattern of individual cells based on the AST. HeLa cells stained with calcein-AM (green) are used to represent the size and profile of the trapping point. The white arrow represents the direction of lateral flow, the red arrows show the trajectories of individual cells in SteAS, the white dotted pentagon is the position of the UHF device, and the blue curved rectangles represent the profile of the AST. e A single cluster trapped in the AST. The cells are highlighted by pseudocolor (red). The detailed images show the images before and after image processing. The rotation axis and direction are represented by a blue dotted line and a blue arrow, respectively. f The result of <t>3D</t> <t>reconstruction.</t>
    3d Reconstructions Image Processing Software, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/3d+reconstruction+image+processing/10__1016_slash_j__clay__2014__08__015-78-11-19
    Average 90 stars, based on 1 article reviews
    3d reconstructions image processing software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    99
    Oxford Instruments 3d acinar reconstruction image processing
    a SteAS-based trapping of a single fluorescent PS particle (5 μm). When the power was applied, particles are trapped and suspended in the microchannel. b When the power is turned off, the particles settle to the surface. c A suspended particle is trapped and rotated in the AST under the combined effect of radiation force and drag force. The stacked image sequences (6 images, 27 ms apart) are captured at approximately 10 mW. The green dotted circle represents the range of trapping points. The red arrows show the direction of particle rotation. The yellow dotted rectangle shows the position of the UHF device. d Pattern of individual cells based on the AST. HeLa cells stained with calcein-AM (green) are used to represent the size and profile of the trapping point. The white arrow represents the direction of lateral flow, the red arrows show the trajectories of individual cells in SteAS, the white dotted pentagon is the position of the UHF device, and the blue curved rectangles represent the profile of the AST. e A single cluster trapped in the AST. The cells are highlighted by pseudocolor (red). The detailed images show the images before and after image processing. The rotation axis and direction are represented by a blue dotted line and a blue arrow, respectively. f The result of <t>3D</t> <t>reconstruction.</t>
    3d Acinar Reconstruction Image Processing, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/3d+reconstruction+image+processing/Imaris/pmc02536812-70-8-28
    Average 99 stars, based on 1 article reviews
    3d acinar reconstruction image processing - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    Image Search Results


    Imaris snapshot images of confocal z-stack projections that visualise the entire depth of the retinal fibre layer where both astrocytes and blood vessels are situated. The overlapping immunohistochemistry represents connexin heterogeneity in gap junction plaques expressed by astrocytes and captured using high resolution three-dimensional projection, simulated fluorescence processing and orthogonal mode camera dialogue. The GFAP and GS isolectin B4 stain were omitted from these images to better illustrate the fluorescence of the connexins. A&C were taken in the central retinal region and B&D from a peripheral retinal region. A&C and B&D are a different angle of the same 3D analysis to show different connexin combinations as indicated by the arrows. Immunostaining of astrocyte connexins represents Cx26 (blue), Cx30 (red), Cx43 (green) and Cx45 (brown). Different colocalisation patterns of connexin proteins in diverse astrocyte connexin hemichannels were qualitatively analysed (1Cx protein, small arrows, 2Cx and 3Cx proteins, curved arrows, and 4Cx proteins, large arrowheads). All images are highly zoomed and rendered confocal z-slice projections. For qualitative purposes, displayed images were also constructed using automated scale bar, object frame (grid, tickmarks and box) and XYZ clipping plane (i.e. crops object below the plane). The set camera angle logarithmic functions were also applied to measure angle, elevation and azimuth parameters for each of the images represented. This was as follows: angle = −5.6521 (A), 4.4572 (B), −6.3247 (C), −0.0729 (D), elevation = 91.8453 (A), 88.6771 (B), 93.7761 (C), 90.0196 (D), azimuth = 119.9393 (A), −65.222 (B), 127.6513 (C), 93.3840 (D).

    Journal: PLoS ONE

    Article Title: Connexin 30 Expression and Frequency of Connexin Heterogeneity in Astrocyte Gap Junction Plaques Increase with Age in the Rat Retina

    doi: 10.1371/journal.pone.0057038

    Figure Lengend Snippet: Imaris snapshot images of confocal z-stack projections that visualise the entire depth of the retinal fibre layer where both astrocytes and blood vessels are situated. The overlapping immunohistochemistry represents connexin heterogeneity in gap junction plaques expressed by astrocytes and captured using high resolution three-dimensional projection, simulated fluorescence processing and orthogonal mode camera dialogue. The GFAP and GS isolectin B4 stain were omitted from these images to better illustrate the fluorescence of the connexins. A&C were taken in the central retinal region and B&D from a peripheral retinal region. A&C and B&D are a different angle of the same 3D analysis to show different connexin combinations as indicated by the arrows. Immunostaining of astrocyte connexins represents Cx26 (blue), Cx30 (red), Cx43 (green) and Cx45 (brown). Different colocalisation patterns of connexin proteins in diverse astrocyte connexin hemichannels were qualitatively analysed (1Cx protein, small arrows, 2Cx and 3Cx proteins, curved arrows, and 4Cx proteins, large arrowheads). All images are highly zoomed and rendered confocal z-slice projections. For qualitative purposes, displayed images were also constructed using automated scale bar, object frame (grid, tickmarks and box) and XYZ clipping plane (i.e. crops object below the plane). The set camera angle logarithmic functions were also applied to measure angle, elevation and azimuth parameters for each of the images represented. This was as follows: angle = −5.6521 (A), 4.4572 (B), −6.3247 (C), −0.0729 (D), elevation = 91.8453 (A), 88.6771 (B), 93.7761 (C), 90.0196 (D), azimuth = 119.9393 (A), −65.222 (B), 127.6513 (C), 93.3840 (D).

    Article Snippet: The size of each Cx plaque was measured in voxels (X, Y and Z dimensions) and pixels (2-dimensions only) following acquisition using Imaris 3D-reconstruction image analysis and processing software (Bitplane Inc, Saint Paul, MN) version 7.0.

    Techniques: Immunohistochemistry, Fluorescence, Staining, Immunostaining, Construct

    a SteAS-based trapping of a single fluorescent PS particle (5 μm). When the power was applied, particles are trapped and suspended in the microchannel. b When the power is turned off, the particles settle to the surface. c A suspended particle is trapped and rotated in the AST under the combined effect of radiation force and drag force. The stacked image sequences (6 images, 27 ms apart) are captured at approximately 10 mW. The green dotted circle represents the range of trapping points. The red arrows show the direction of particle rotation. The yellow dotted rectangle shows the position of the UHF device. d Pattern of individual cells based on the AST. HeLa cells stained with calcein-AM (green) are used to represent the size and profile of the trapping point. The white arrow represents the direction of lateral flow, the red arrows show the trajectories of individual cells in SteAS, the white dotted pentagon is the position of the UHF device, and the blue curved rectangles represent the profile of the AST. e A single cluster trapped in the AST. The cells are highlighted by pseudocolor (red). The detailed images show the images before and after image processing. The rotation axis and direction are represented by a blue dotted line and a blue arrow, respectively. f The result of 3D reconstruction.

    Journal: Microsystems & Nanoengineering

    Article Title: Manipulation of single cells via a Stereo Acoustic Streaming Tunnel (SteAST)

    doi: 10.1038/s41378-022-00424-9

    Figure Lengend Snippet: a SteAS-based trapping of a single fluorescent PS particle (5 μm). When the power was applied, particles are trapped and suspended in the microchannel. b When the power is turned off, the particles settle to the surface. c A suspended particle is trapped and rotated in the AST under the combined effect of radiation force and drag force. The stacked image sequences (6 images, 27 ms apart) are captured at approximately 10 mW. The green dotted circle represents the range of trapping points. The red arrows show the direction of particle rotation. The yellow dotted rectangle shows the position of the UHF device. d Pattern of individual cells based on the AST. HeLa cells stained with calcein-AM (green) are used to represent the size and profile of the trapping point. The white arrow represents the direction of lateral flow, the red arrows show the trajectories of individual cells in SteAS, the white dotted pentagon is the position of the UHF device, and the blue curved rectangles represent the profile of the AST. e A single cluster trapped in the AST. The cells are highlighted by pseudocolor (red). The detailed images show the images before and after image processing. The rotation axis and direction are represented by a blue dotted line and a blue arrow, respectively. f The result of 3D reconstruction.

    Article Snippet: The image processing and 3D reconstruction were achieved by MATLAB software (USA).

    Techniques: Staining